Dipl.-Ing. Jan Stelzner
Roles
Research Assistant
Research
Research Interests
- Magnetic Particle Imaging
Involved Projects
Curriculum Vitae
JAN STELZNER was born in Lübeck, Germany in 1986. He received his Dipl.-Ing. in Electrical Engineering in 2013 from the Technical University Hamburg-Harburg, Germany. In 2013 he wrote his diploma thesis at the institute of measurement engineering of the TUHH about the development and construction of a phased-array-antenna in the 2.4 GHz frequency band. He is a Research Assistant at the Institute of Medical Engineering since November 2013.
Publications
2022 [ to top ]
- Stelzner, J., Bakenecker, A. C., Behrends, A., Bringout, G., Chen, X., von Gladiss, A., Gräfe, K., Schumacher, J. and Buzug, T. M.: Implementation and imaging with a versatile 180 mm magnetic particle imaging field generator, Journal of Magnetism and Magnetic Materials, 169509, 2022, DOI: 10.1016/j.jmmm.2022.169509.
2021 [ to top ]
- Behrends, A., Bakenecker, A., Ahlborg, M., Gräfe, K., Schumacher, J., Stelzner, J., Wegner, F., Neumann, A., Blancke Soares, Y., Lüdtke-Buzug, K., Chen, X., Wei, H., Malhotra, A., Friedrich, T. and Buzug, T. M.: Magnetic particle imaging, In: Imaging Modalities for Biological and Preclinical Research: A Compendium, IOP Publishing, , II.8-1 to II.8-10, 2021, DOI: 10.1088/978-0-7503-3747-2ch12.
2020 [ to top ]
- Stelzner, J., Gräfe, K. and Buzug, T. M.: First images obtained with a rabbit-sized Magnetic Particle Imaging scanner, International Journal on Magnetic Particle Imaging, Vol 6 No 2 Suppl. 1 (2020), 2020, DOI: https://doi.org/10.18416/IJMPI.2020.2009033.
2019 [ to top ]
- Stelzner, J., Gräfe, K., von Gladiss, A., Beuke, J. and Buzug, T. M.: A Rabbit Sized Field-Free-Line Magnetic-Particle-Imaging Scanner - Past, Present, and Future, In: 9th International Workshop on Magnetic Particle Imaging, 239, 2019.[ BibTeX ]
2018 [ to top ]
- Stelzner, J., Beuke, J., Wei, H. and Buzug, T. M.: A Customized Highly Linear Power Resistor For Distortion Measurements in a Magnetic Particle Imaging Signal Chain, In: 52th Annual Conference of the German Society for Biomedical Engineering, 2018.[ BibTeX ]
- Stelzner, J., Weber, M. and Buzug, T. M.: A Receive Coil Topology Based on Oppositely Tilted Solenoids for a Predefined Drive Field, In: International Workshop on Magnetic Particle Imaging, 81-82, 2018.[ BibTeX ]
2017 [ to top ]
- Bakenecker, A., Friedrich, T., von Gladiss, A., Graeser, M., Stelzner, J. and Buzug, T. M.: Experimental Validation of the Selection Field of a Rabbit-Sized FFL Scanner, International Journal on Magnetic Particle Imaging, 3(1), 2017, DOI: 10.18416/IJMPI.2017.1703013.
- Stelzner, J., Graeser, M., Bakenecker, A., von Gladiss, A., Bringout, G. and Buzug, T. M.: Measurements Inside a Rabbit Sized FFL-MPI Device Using a Gradiometric Receive Coil, International Journal on Magnetic Particle Imaging, 3(1), 2017, DOI: 10.18416/IJMPI.2017.1703012.
- Bakenecker, A., Friedrich, T., von Gladiss, A., Graeser, M., Stelzner, J. and Buzug, T. M.: Experimental Validation of the Selection Field of a Rabbit Sized FFL Scanner, In: International Workshop on Magnetic Particle Imaging, 41, 2017.[ BibTeX ]
- Stelzner, J. and Buzug, T. M.: Magnetic-Field Measurement and Simulation of a Field-Free Line Magnetic-Particle Scanner, Current Directions in Biomedical Engineering, 3(2), 837 -- 840, 2017, DOI: https://doi.org/10.1515/cdbme-2017-0191.[ BibTeX ]
2016 [ to top ]
- Stelzner, J., Bringout, G., von Gladiss, A., Medimagh, H., Ahlborg, M., Sattel, T. F. and Buzug, T. M.: First Spectrum Measurements with a Rabbit-Sized FFL-Scanner, In: International Workshop on Magnetic Particle Imaging, 138, 2016.[ BibTeX ]
2015 [ to top ]
- Stelzner, J., Bringout, G., Graeser, M. and Buzug, T. M.: Toriodal Variometer for a Magnetic Particle Imaging Device, In: International Workshop on Magnetic Particle Imaging, 92, 2015, DOI: 10.1109/IWMPI.2015.7107074.[ BibTeX ]
- Graeser, M., Ahlborg, M., Behrends, A., Bente, K., Bringout, G., Debbeler, C., v. Gladiß, A., Gräfe, K., Kaethner, C., Kaufmann, S., Lüdtke-Buzug, K., Medimagh, H., Stelzner, J., Weber, M. and Buzug, T. M.: A Device for Measureing the Trajectorey Dependent Magnetic Particle Performance for MPI, In: International Workshop on Magnetic Particle Imaging, 2015, DOI: 10.1109/IWMPI.2015.7107078.
- Bringout, G., Stelzner, J., Ahlborg, M., Behrends, A., Bente, K., Debbeler, C., von Gladiß, A., Gräfe, K., Graeser, M., Kaethner, C., Kaufmann, S., Lüdtke-Buzug, K., Medimagh, H., Tenner, W., Weber, M. and Buzug, T. M.: Concept of a Rabbit-Sized FFL-Scanner, In: International Workshop on Magnetic Particle Imaging, 49, 2015.[ BibTeX ]
- Panagiotopoulos, N., Duschka, R. L., Ahlborg, M., Bringout, G., Debbeler, C., Graeser, M., Kaethner, C., Lüdtke-Buzug, K., Medimagh, H., Stelzner, J., Buzug, T. M., Barkhausen, J., Vogt, F. and Haegele, J.: Magnetic particle imaging: current developments and future directions, International Journal of Nanomedicine, 10, 3097-3114, 2015, DOI: 10.2147/ijn.s70488.
2014 [ to top ]
- Behrends, A., Graeser, M., Stelzner, J. and Buzug, T. M.: Signal Chain Optimization in Magnetic Particle Imaging, In: Deutsche Gesellschaft für Biomedizinische Technik Jahrestagung, 526--529, 2014, DOI: 10.1515/bmt-2014-5008.
- Bringout, G., Ahlborg, M., Graeser, M., Kaethner, C., Stelzner, J., Tenner, W., Wojtczyk, H. and Buzug, T. M.: Shielded drive coils for a rabbit sized FFL scanner, In: International Workshop on Magnetic Particle Imaging, 98, 2014.[ BibTeX ]
- Stelzner, J., Graeser, M. and Buzug, T. M.: Design and Construction of a Toroidal Filter Coil for a Magnetic Particle Imaging Device, In: Deutsche Gesellschaft für Biomedizinische Technik Jahrestagung, 679--682, 2014, DOI: 10.1515/bmt-2014-4280.[ BibTeX ]