Dipl.-Inf. Maik Stille

Institut für Medizintechnik

Universität zu Lübeck
Ratzeburger Allee 160
23562 Lübeck
Gebäude 64, Raum 063

Email:stille(at)imt.uni-luebeck.de
Phone:+49 451 3101 5413
Fax:+49 451 3101 5404

Role

Research Associate


Research

Research Interests

  • Computed Tomography
  • Metal-Artifact Reduction
  • Image Registration
  • Neuroimaging

Involved Projects

  • Computed Tomography
  • Metal-Artifact Reduction

Curriculum Vitae

Maik Stille was born in Greifswald, Germany in 1984. He received his Dipl.-Inf. from the University of Lübeck in 2011.  He wrote his diploma thesis at King's College London, Institute of Psychiatry, Department of Neuroimaging in the field of image registration. Since October 2011 he is a student of the Graduate School for Computing in Medicine and Life Sciences and works at the Institute of Medical Engineering.


Publications

[ 2019 ] [ 2018 ] [ 2017 ] [ 2016 ] [ 2015 ] [ 2013 ] [ 2012 ] [ 2010 ] [ 2009 ]

2019 [ to top ]

  • von Gladiss, A., Beuke, J., Weber, M., Malhotra, A., Behrends, A., Cordes, A., Stille, M., Behr, V. C., Vogel, P., Gräfe, K., Friedrich, T., Lüdtke-Buzug, K., Neumann, A., Ahlborg, M. and Buzug, T. M.: Dynamic 2D Imaging with an MPI Scanner Featuring a Mechanically Rotated FFL, In: 9th International Workshop on Magnetic Particle Imaging, 5, 2019.
     
  • Wattenberg, M., Stille, M., Klein, P. and Buzug, T. M.: 2D Contour Reconstruction for Industrial Computed Tomography using Crease Cluster, e-Journal of Nondestructive Testing, 2019.
     

2018 [ to top ]

  • Ziemann, C., Stille, M., Cremers, F., Buzug, T. M. and Rades, D.: Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction, Journal of Applied Clinical Medical Physics, 19(3), 227--233, 2018, DOI: 10.1002/acm2.12325.
     
  • Heinrich, M. P., Stille, M. and Buzug, T. M.: Residual U-Net Convolutional Neural Network Architecture for Low-Dose CT Denoising, Current Directions in Biomedical Engineering, 4(1), 297--300, 2018, DOI: 10.1515/cdbme-2018-0072.
     

2017 [ to top ]

  • Ziemann, C., Stille, M., Cremers, F., Rades, D. and Buzug, T. M.: The effects of metal artifact reduction on the retrieval of attenuation values, Journal of applied clinical medical physics, 18(1), 243--250, 2017, DOI: 10.1002/acm2.12002.
     

2016 [ to top ]

  • Stille, M. and Buzug, T. M.: Augmented likelihood image reconstruction with non-local prior image regularization, In: Proc. 4th Intl. Mtg. on image formation in X-ray CT, 145--8, 2016.
     
  • Stille, M., Kleine, M., Hagele, J., Barkhausen, J. and Buzug, T. M.: Augmented Likelihood Image Reconstruction, IEEE Transactions on Medical Imaging, 35(1), 158-173, 2016, DOI: 10.1109/TMI.2015.2459764.
     

2015 [ to top ]

  • Stille, M. and Buzug, T. M.: Metal artifact reduction by projection replacements and non-local prior image integration, Current Directions in Biomedical Engineering, 1(1), 100-103, 2015, DOI: 10.1515/cdbme-2015-0026.
     

2013 [ to top ]

  • Stille, M., Kratz, B., Müller, J., Maaß, N., Schasiepen, I., Elter, M., Weyers, I. and Buzug, T. M.: Influence of metal segmentation on the quality of metal artifact reduction methods, In: SPIE Medical Imaging, 86683C, 2013, DOI: 10.1117/12.2006810.
     
  • Stille, M., Smith, E. J., Crum, W. R. and Modo, M.: 3D reconstruction of 2D fluorescence histology images and registration with in vivo MR images: Application in a rodent stroke model, Journal of Neuroscience Methods, 219(1), 27-40, 2013, DOI: 10.1016/j.jneumeth.2013.06.003.
     

2012 [ to top ]

  • Mueller, J., Kaiser, F., Levakhina, Y. M., Stille, M., Weyers, I. and Buzug, T. M.: An open database of metal artifacts cases for clinical CT imaging, In: Image Formation in X-Ray Computed Tomography, 210-213, 2012.
     

2010 [ to top ]

  • Stille, M. and Finke, M.: Combination of a Robotic Surgical Microscope and an Augmented Reality for Intraoperative Navigation, In: Deutsche Gesellschaft für Biomedizinische Technik Jahrestagung, 2010.
     

2009 [ to top ]

  • Finke, M., Meyer, T., Stille, M. and Schweikard, A.: Automatic Positioning of a Surgical Microscope, In: Jahrestagung der Gesellschaft für Informatik, 998-1009, 2009.
     

Thesis and Reports

M. Stille, Reconstruction of a 3-dimensional Brain Volume from Fluorescent Images and its Co-Registration with Magnetic Resonance Imaging, Diplomarbeit, Institute of Psychiatry, Department of Neuroimaging, King's College London, London, United Kingdom, 2011.